Bussmann Bussmann-BP/SL-20 BP/SL-20 20 Amp Time Delay Loaded Link Rejection Base Plug Fuse, 125V UL Listed Carded, 3-Pack, No Color

$10.96

No-interchangeability prevents installing a higher amp fuse than the circuit was designed for and Edison base plug fuses, 125 Vac dual-element, Time-delay.
Used for air conditioners, furnace blower motors, swimming pool pumps, deep freezers or any circuit where motors frequently turn ON and OFF
Heavy Duty Time-Delay Plug Fuse used to protect critical motor circuits or motors that cycle on/off frequently

Category:

Description

Product Description

3 Pack, 20A Type SL Plug Fuse, Non Tamp, Dimensions: 1.83″L x 0.917″W x 0.417″H, Carded. Manufactured in China. From the Manufacturer SL fuse for residential motor circuits in kitchens, workshops, garages, utility rooms or any circuit with motors, relays or solenoids. The rejection base threads prevent a larger amp fuse from being used. Example: A 30 amp fuse cannot be installed in a 20 amp receptacle because of the different sized threads. Medium-duty fuse. These fuses thread into fuse receptacles. Threaded fuse type: Rejection Base (porcelain threads). Not interchangeable with Edison Base (brass threads) type. Medium-duty (SL) category plug fuse. The medium-duty fuse (SL) has a time-delay feature for use on motor circuits. Plug fuses are rated for a maximum of 125Vac. SL three pack (PK3) version (blister pack). Plug fuses are often used in residential and industrial branch circuit and motor protection. Fuses are used to protect furnace blower motors, pumps, power tools, garage door openers, etc. Motor protection fuses are usually used in conjunction with branch circuit protection. The fuse is often located in a box cover unit. Plug fuses provide a compact and inexpensive method to prevent damage to electrical motors. They help reduce downtime and lower maintenance costs by opening the circuit when a dangerous overload is present. When used for residential branch circuit protection, fuses are typically located in the main fuse panel.

From the Manufacturer

SL fuse for residential motor circuits in kitchens, workshops, garages, utility rooms or any circuit with motors, relays or solenoids. The rejection base threads prevent a larger amp fuse from being used. Example: A 30 amp fuse cannot be installed in a 20 amp receptacle because of the different sized threads. Medium-duty fuse. These fuses thread into fuse receptacles. Threaded fuse type: Rejection Base (porcelain threads). Not interchangeable with Edison Base (brass threads) type. Medium-duty (SL) category plug fuse. The medium-duty fuse (SL) has a time-delay feature for use on motor circuits. Plug fuses are rated for a maximum of 125Vac. SL three pack (PK3) version (blister pack). Plug fuses are often used in residential and industrial branch circuit and motor protection. Fuses are used to protect furnace blower motors, pumps, power tools, garage door openers, etc. Motor protection fuses are usually used in conjunction with branch circuit protection. The fuse is often located in a box cover unit. Plug fuses provide a compact and inexpensive method to prevent damage to electrical motors. They help reduce downtime and lower maintenance costs by opening the circuit when a dangerous overload is present. When used for residential branch circuit protection, fuses are typically located in the main fuse panel.

No-interchangeability prevents installing a higher amp fuse than the circuit was designed for and Edison base plug fuses, 125 Vac dual-element, Time-delay.
Used for air conditioners, furnace blower motors, swimming pool pumps, deep freezers or any circuit where motors frequently turn ON and OFF
Heavy Duty Time-Delay Plug Fuse used to protect critical motor circuits or motors that cycle on/off frequently
An industrial/commercial grade product with exclusive dual element construction. Edison base size. These fuses thread into fuse receptacles
Will withstand typical motor starting surges, Use in residential or light-duty circuits that contain electric motors, These fuses thread into fuse receptacles.
Size Rejecting Plug Fuse
No-interchangeability prevents installing a higher amp fuse than the circuit was designed for
Has ability to withstand typical motor starting surges
Use in residential or light-duty motor circuits
This fuse threads into SA adaptors

Additional information

AC Adapter Current

Brand

Voltage

Item Dimensions LxWxH

Material

Mounting Type

Manufacturer

Part Number

Item Weight

Product Dimensions

Country of Origin

Item model number

Is Discontinued By Manufacturer

,

Color

Included Components

Warranty Description

Date First Available

Brand

Bussman Fuses

Bussmann Fuses, a trusted leader in the electrical industry, specializes in high-quality fuses and electrical components designed for various applications, including industrial, residential, and commercial. With a strong commitment to safety and performance, Bussmann Fuses deliver reliable protection for your electrical systems. Discover an extensive selection of Bussmann products at competitive prices on Electric Depot, powered by Amazon, and ensure the safety and efficiency of your electrical installations.